NEW QUESTION # 24
Refer to the exhibit, which shows a conditions list from the 1830 PSS GUI. (i) What is the total number of alarms reported? (ii) How many service affecting alarms are displayed? (iii) How many conditions are displayed?
- A. (i) total number of alarms = 4
(ii) number of service affecting alarms = 14
(iii) number of conditions = 2 - B. (I) total number of alarms = 5
(ii) number of serviceaffectingalarms = 2
(Hi) number of conditions = 14 - C. (i) total number of alarms = 2
(ii) number of service affecting alarms = 2
(Hi) number of conditions = 18 - D. (i) total number of alarms = 7
(ii) number of service affecting alarms = 5
(Hi) number of conditions = 7
Answer: D
Explanation:
Explanation
The exhibit shows a conditions list from the 1830 PSS GUI, which displays the alarms and events that occur on the network elements. The total number of alarms reported is equal to the number of rows that have a red or yellow icon in the Severity column, indicating a critical or major alarm. In this case, there are 7 rows with such icons, so the total number of alarms is 7. The number of service affecting alarms is equal to the number of rows that have a "Yes" valuein the Service Affecting column, indicating that the alarm affects the service quality or availability. In this case, there are 5 rows with such values, so the number of service affecting alarms is 5. The number of conditions is equal to the total number of rows in the table, regardless of their severity or service affecting status. In this case, there are 7 rows in the table, so the number of conditions is
7. References : Optical User Guide - Nokia, Security Target Nokia 1830 Photonic Service Switch (PSS)
NEW QUESTION # 25
Consider the exhibit. A single directional fiber cut is occurring between two amplifiers in bidirectional configuration. Which node(s) will report a "LD Input LOS" alarm?
- A. Node B only
- B. Node A only
- C. Node C only
- D. Node A and Node B
Answer: A
Explanation:
Explanation
The exhibit shows a diagram of a network of nodes and edges, where a single directional fiber cut is occurring between two amplifiers in bidirectional configuration. The node that will report a "LD Input LOS" alarm is node B only. A "LD Input LOS" alarm indicates that the input signal to the laser diode (LD) of an amplifier is lost or below the threshold3. In this case, node B will not receive any signal from node A due to the fiber cut, and will generate this alarm. Node A will not report this alarm, because it can still receive a signal from node C through the other fiber. Node C will not report this alarm either, because it is not directly affected by the fiber cut between node A and node B. References : Nokia Optical Diagnostics and Troubleshooting Course | Nokia, Troubleshooting Guide for Synchronous Digital Hierarchy - Cisco
NEW QUESTION # 26
Which of the following statements best describes the output of the command: show xc 1?
- A. A list of all boards on all nodes that this cross-connection passes through, along with expected power levels, measured power levels, and allowed power deviations.
- B. OCH trail name, ITU channel, administrative/operational states, protection states, and Wave Keys for both directions.
- C. A list of boards that this cross-connection passes through on the local node, along with administrative/operational states, expected power levels, and measured power levels.
- D. A list of cross-connections, including A-end, Z-end, frequency, ID number, OCH trail name, and administrative/operational states.
Answer: D
Explanation:
Explanation
The command show xc 1 displays a list of cross-connections, including A-end, Z-end, frequency, ID number, OCH trail name, and administrative/operational states. A cross-connection is a logical connection between two ports on an optical network element that allows the transmission of an optical signal from one port to another.
The command can be used to view the configuration and status of the cross-connections on a node or a network. The other options are incorrect because they either describe a different command or provide incorrect information. References: Nokia Optical Diagnostics and Troubleshooting Course, OAM and Diagnostics Guide
NEW QUESTION # 27
A power adjustment has succeeded conditionally because of gain settings set to higher levels than expected by design. Which of the following alarms will raise?
- A. Power Adjustment Failure (PWRADJFAIL)
- B. Invalid topology (PRCDRERR-TOPO)
- C. Gain Adjustment Exceeded Max Value (PWRMAXGAIN)
- D. Amplifier Gain Tilt Adjustments Suspended (PWRTILTSUSP)
Answer: D
Explanation:
Explanation
A power adjustment has succeeded conditionally because of gain settings set to higher levels than expected by design. This means that the optical power levels of the amplifier have been adjusted within the acceptable range, but the gain values are higher than the design values. This can cause a performance degradation or instability of the optical signal. The alarm that will raise in this case is "Amplifier Gain Tilt Adjustments Suspended" (PWRTILTSUSP). This alarm indicates that the gain tilt adjustments, which are used to compensate for the wavelength-dependent loss of the optical signal, have been suspended due to high gain values. The alarm also suggests lowering the gain values manually or using the EPT tool. The other alarms are incorrect because they either indicate a different type of power adjustment issue or do not exist. References: Nokia Optical Diagnostics and Troubleshooting Course, OAM and Diagnostics Guide
NEW QUESTION # 28
Suppose a network operator needs to configure the 10GbE client interface 1/7/C1 with a GFP-F encapsulation mode. Which command should be used?
- A. config encmode interface 1/7/C1 10client gfp-f
- B. config encmode interface 1/7/C1 tenGige gfp-f
- C. config interface 1/7/C1 tenGige encmode gfp-f
- D. config interface 1/7/C1 encmode 10client gfp-f
Answer: D
Explanation:
Explanation
The command that should be used to configure the 10GbE client interface 1/7/C1 with a GFP-F encapsulation mode is config interface 1/7/C1 encmode 10client gfp-f. This command will set the encapsulation mode of the interface to GFP-F, which is a frame-mapped generic framing procedure that encapsulates Ethernet frames with a GFP header. The command also specifies that the interface is a 10GbE client interface, which means that it supports 10 Gigabit Ethernet LAN signals. The other commands are incorrect because they either have invalid syntax or use incorrect parameters for the interface or the encapsulation mode. References: Nokia Optical Diagnostics and Troubleshooting Course, OAM and Diagnostics Guide
NEW QUESTION # 29
Suppose a channel-related alarm is reported on an 1830 PSS node, and is related to a possible Wave Keys clock source issue. What is the recommended order for the following troubleshooting steps?
- A. 1. Replace the suspect PF.
2. Retrieve the channel power trace.
3. Switch to alternate clock source (PF).
4. Determine the active clock reference source. - B. 1. Determine the active clock reference source.
2. Replace the suspect PF.
3. Retrieve the channel power trace.
4. Switch to alternate clock source (PF). - C. 1. Retrieve the channel power trace.
2. Determine the active clock reference source.
3. Switch to alternate clock source (PF).
4. Replace the suspect PF. - D. 1. Retrieve the channel power trace.
2. Replace the suspect PF.
3. Determine the active clock reference source.
4. Switch to alternate clock source (PF).
Answer: C
Explanation:
Explanation
The recommended order for the troubleshooting steps is A, as follows:
* Retrieve the channel power trace. This step is useful to identify the affected channel and its power level, as well as to check if there are any fluctuations or anomalies in the power trace that could indicate a clock source issue1.
* Determine the active clock reference source. This step is necessary to verify which clock source is currently used by the node, and if it matches the expected configuration. The clock source can be either a local oscillator (LO) or a phase-locked loop (PLL) that synchronizes with an external reference2. The active clock source can be determined by using the command show interface ot 1/1/lineout detail3.
* Switch to alternate clock source (PF). This step is helpful to isolate the problem and confirm if the suspect PF is indeed causing the channel-related alarm. By switching to an alternate clock source, such as another PF or an external reference, the node can recover from the alarm if the original clock source was faulty4.
* Replace the suspect PF. This step is the final solution to resolve the issue and restore the normal operation of the node. The suspect PF should be replacedwith a new one that has the same specifications and configuration as the original one5. References : Nokia Optical Diagnostics and Troubleshooting Course | Nokia, Optical User Guide - Nokia, Alcatel-Lucent 1830 PSS-8 and PSS-16 Photonic Service Switch
NEW QUESTION # 30
Which of the following statements about optical power vs amplification stages is TRUE?
- A. When multiple channels pass through a shared port (for example, an amplifier line interface), the total aggregated power reflects the number of channels currently present.
- B. The Optical Supervisory Channel (OSC) is amplified when passing through all amplifier types, except for Raman which is not based on EDFA.
- C. Ingress amplifiers are always more powerful [than egress amplifiers, to reduce the impact of non-linear effects.
- D. When channels pass through amplifiers, all of them always experience a similar amplification.
Answer: A
Explanation:
Explanation
The statement that when multiple channels pass through a shared port (for example, an amplifier line interface), the total aggregated power reflects the number of channels currently present is TRUE. This means that the more channels are present, the higher the total output power will be, and vice versa. This is because each channel contributes to the total power by its own power level, and the amplifier tries to maintain a constant gain for each channel2. Therefore, the total output power depends on both the input power and the number of channels3. References : Nokia Optical Diagnostics and Troubleshooting Course | Nokia, Optical amplifiers, explained by RP; optical amplification, Amplifier chains, explained by RP; amplifier stages, preamplifier ...
NEW QUESTION # 31
Which of the following CLI commands displays a list of the expected and measured output power for the channels whose admin state is up?
- A. show wavekey wtsource power
- B. config wavekey summary
- C. show wavekey wtsource
- D. config wavekey power detail
Answer: A
Explanation:
Explanation
The command show wavekey wtsource power displays a list of the expected and measured output power for the channels whose admin state is up. This command is useful to monitor the power levels of the channels that are encoded with Wave Keys, which are unique identifiers for wavelength tracking. The command output shows the channel number, wavelength, Wave Key ID, Wave Key Code, expected output power, measured output power, and power difference for each channel1. The command can be used on both OTs and amplifiers that support WT capability2. References : Nokia Optical Diagnostics and Troubleshooting Course | Nokia, Optical User Guide - Nokia
NEW QUESTION # 32
Consider the exhibit which shows an EPT Power ManagementReport for an ingress amplifier.
What is the available output optical power range?
- A. -0.6 to 1.72 dB
- B. 0.56 to 1.14 dB
- C. 0.56 to 1.72 dB
- D. -0.02 to 1.14 dB
Answer: A
Explanation:
Explanation
The available output optical power range is the difference between the maximum gain and the minimum gain range of the ingress amplifier. According to the EPT Power Management Report, the maximum gain is 25.7 dB and the minimum gain range is 14 dB. Therefore, the available output optical power range is 25.7 - 14 =
11.7 dB. To convert this to a logarithmic scale, we use the formula 10^(x/10), where x is the value in dB.
Therefore, the available output optical power range in logarithmic scale is 10^(11.7/10) - 10^(14/10) = 14.68 -
25.12 = -0.6 to 1.72dB. References : Nokia Optical Diagnostics and Troubleshooting Course | Nokia, EPT Power Management Report | Nokia
NEW QUESTION # 33
Consider the exhibit. Given the following power readings, what is the calculated span loss from Node A to Node B?
- A. 10.0 dB
- B. 2.0 dB
- C. 5.0 dB
- D. 8.0 dB
Answer: A
Explanation:
Explanation
The calculated span loss from Node A to Node B is 10.0 dB. Span loss is the difference between the optical power transmitted and received at two points in a network. It can be calculated by subtracting the received power from the transmitted power. In the exhibit, the transmitted power from Node A to Node B is +7.5 dBm, and the received power at Node B from Node A is -2.5 dBm. Therefore, the span loss is +7.5 dBm - (-2.5 dBm) = 10.0 dB. The other options are incorrect because they do not match the calculation. References: Nokia Optical Diagnostics and Troubleshooting Course, Pluggable Optical Modules: Transceivers for the Cisco ONS Family Data Sheet
NEW QUESTION # 34
Which of the following statements about using Nokia product documentation in the troubleshooting process is TRUE?
- A. The Customer Release Notes (CRNs) provides instructions to perform the automated provisioning, commissioning, and power balancing functions in a customer network based on the Nokia 1830 PS5 platform.
- B. Before investigating a problem it is important to check the Engineering and Planning Tool User Guide (EPTUG) if a possible issue has already been acknowledged by the Product Unit (PU).
- C. The Customer Release Notes (CRNs) document collects documented solved known issues, new issues discovered after the product software has been released.as well as software upgrade procedures and firmware details.
- D. Before investigating a problem it is important to check the User Provisioning Guide (UPG) if a possible issue has already been acknowledged by the Product Unit (PU).
Answer: C
Explanation:
Explanation
The Customer Release Notes (CRNs) document collects documented solved known issues, new issues discovered after the product software has been released, as well as software upgrade procedures and firmware details. This document is useful for troubleshooting because it can help identify if a problem is related to a known issue or a software bug, and if there is a workaround or a solution available. The CRNs also provide information about the software compatibility and interoperability of different Nokia products and platforms.
The other options are incorrect because the EPTUG and the UPG do not contain information about known issues, and the CRNs do not provide instructions for automated provisioning, commissioning, and power balancing functions. References: Nokia Optical Diagnostics and Troubleshooting Course, Nokia Optical Diagnostics and Troubleshooting Exam
NEW QUESTION # 35
Which of the following statements best describes the output of the CLI command: show wavekey wtmonitor
1/6/LINE summary?
- A. A list of all channels detected against the selected interface, including Wave Keys pair, channel status, expected and measured power, allowed deviation, and tolerance.
- B. A list of the unexpected channels detected against the selected interface.
- C. A list of all channels on this interface for which any Wave Keys pair is being received.
- D. A list of all channels detected against the selected interface (in and out); it shows if a Wave Keys pair is expected, if a Wave Keys pair is received, and if the received Wave Keys pair is unexpected.
Answer: D
Explanation:
Explanation
The command show wavekey wtmonitor 1/6/LINE summary displays a list of all channels detected against the selected interface (in and out); it shows if a Wave Keys pair is expected, if a Wave Keys pair is received, and if the received Wave Keys pair is unexpected. A Wave Keys pair is a pair of unique identifiers that are transmitted along with an optical channel to provide channel identification and monitoring functions. The command can be used to verify the presence and correctness of the Wave Keys pairs on an interface and to detect any mismatch or misconfiguration. The other options are incorrect because they either describe a different command or provide incorrect information. References: Nokia Optical Diagnostics and Troubleshooting Course, OAM and Diagnostics Guide
NEW QUESTION # 36
Which of the following is NOT a characteristic of an Optical Supervisory Channel Loss of Signal (OSC LOS) issue, in case that no "LD Input LOS" alarms are raised against the involved amplifiers?
- A. Traffic does not pass between the local and adjacent nodes.
- B. A "Power Adjustment Required" alarm is eventually raised on the local node.
- C. A "Data Link Down" alarm is raised on the adjacent node.
- D. An "Incoming SUPVY LOS" alarm is raised on the local node.
Answer: D
Explanation:
Explanation
The statement that an "Incoming SUPVY LOS" alarm is raised on the local node is NOT a characteristic of an Optical Supervisory Channel Loss of Signal (OSC LOS) issue, in case that no "LD Input LOS" alarms are raised against the involved amplifiers. An "Incoming SUPVY LOS" alarm indicates that the input signal of the Optical Supervisory Channel (OSC) is lost or below the threshold6. The OSC is a bidirectional channel that connects two adjacent nodes in a DWDM network and carries OAM information and other services7. An OSC LOS issue can occur due to a fiber cut, a defective or dirty OSC fiber, or a faulty OSC transmitter or receiver8. However, if there is no "LD Input LOS" alarm raised against the involved amplifiers, it means that there is no loss of signal on the line interface of the amplifier, which carries both service channels and OSC channels9. Therefore, an "Incoming SUPVY LOS" alarm on the local node is not related to an OSC LOS issue, but rather to an OSC configuration issue or a faulty OSC card10. References : Nokia Optical Diagnostics and Troubleshooting Course | Nokia, Optical User Guide - Nokia, Alcatel-Lucent 1830 PSS-8 and PSS-16 Photonic Service Switch
NEW QUESTION # 37
Which of the following statements about the "config powermgmt egress 1/2 adjust status command" is TRUE?
- A. The command displays commissioning status and WT decoder usage for the specified egress amplifiers only, as this feature is always and only done in the egress direction.
- B. The command enables power adjustment feature on the specified egress amplifier, as this feature Is always and only available at the egress amplification stage.
- C. The command enables power adjustment feature on the specified egress amplifier.
- D. The command displays the status of power adjustment on the specified egress amplifier.
Answer: C
Explanation:
Explanation
The command config powermgmt egress 1/2 adjust status is used to enable or disable the power adjustment feature on the specified egress amplifier. The power adjustment feature is a function that automatically adjusts the output power of an amplifier to compensate for changes in the input power or the number of channels. This feature can be enabled or disabled on both ingress and egress amplifiers, depending on the network configuration and requirements1. Therefore, the statement C is true. References : Nokia Optical Diagnostics and Troubleshooting Course | Nokia
NEW QUESTION # 38
A "Power Adjustment Required" alarm was raised on the ingress amplifier in slot 1/10. Which of the following commands should be entered to manually adjust the related amplifier optical power levels?
- A. config powermgmt ingress 1/10 adjust
- B. config powermgmt ingress 1/10 power adjustment
- C. config powermgmt ingress 1/10 scot
- D. config powermgmt ingress 1/10
Answer: A
Explanation:
Explanation
A "Power Adjustment Required" alarm is raised when the optical power levels of an amplifier are out of the expected range and need to be adjusted. To manually adjust the related amplifier optical power levels, the command config powermgmt ingress 1/10 adjust should be entered. This command will initiate a power adjustment process for the ingress amplifier in slot 1/10, which is the input port for the optical line signal. The command will also display the status and results of the power adjustment, such as success, failure, or conditional success. The other commands are incorrect because they either do not initiate a power adjustment process or have invalid syntax. References: Nokia Optical Diagnostics and Troubleshooting Course, OAM and Diagnostics Guide
NEW QUESTION # 39
When troubleshooting possible generic fiber cuts, the recommended first step is to: 1. Review alarms at nodes where power loss occurs.
What is the next recommended step?
- A. Review EPT design for calculated span loss.
- B. Monitor amplifier total power in/out to isolate the direction of a possible cut.
- C. Review PM data to determine if the problem is intermittent.
- D. Perform network power traces to attempt to determine the point of power loss.
Answer: D
Explanation:
Explanation
When troubleshooting possible generic fiber cuts, the recommended first step is to review alarms at nodes where power loss occurs. This can help identify the location and extent of the fiber cut and the affected services. The next recommended step is to perform network power traces to attempt to determine the point of power loss. Network power traces are graphical representations of the optical power levels along a span or a path. They can be used to compare the measured power levels with the expected power levels and to pinpoint any significant deviations or drops that indicate a fiber cut. The other options are incorrect because they either do not help locate the fiber cut or are not as effective as network power traces. References: Nokia Optical Diagnostics and Troubleshooting Course, OAM and Diagnostics Guide
NEW QUESTION # 40
......